MVAC Passenger Air Conditioning in Vehicles[7] |
MVAC Passenger Air Conditioning in Buses and Trains[8] |
Centrifugal Chillers[9] |
Positive Displacement Chillers[10] |
Industrial Process Refrigeration[11] |
Cold Storage Warehouse[12] |
Commercial Ice Machines[13] |
Household Refrigerators and Freezers[14] |
Ice Skating Rinks[15] |
Industrial Process Air Conditioning[16] |
Residential and Light Commercial Air Conditioning and Heat Pumps[17] |
Residential Dehumidifiers[18] |
Refrigerated Transport[19] |
Stand Alone Equipment[20] |
Refrigerated Food Processing and Dispensing Equipment[21] |
Remote Condensing Units[22] |
Typical Supermarket Systems[23] |
Vending machines[24] |
Very Low Temperature Refrigeration[25] |
Water Coolers[26]
|
Ammonia / Water Absorption
|
|
|
Acceptable |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Ammonia Absorption
|
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
|
|
|
|
|
|
|
|
Ammonia Vapor Compression
|
|
|
Acceptable |
|
Acceptable |
Acceptable |
Acceptable |
|
Acceptable |
Acceptable |
|
|
|
|
|
|
|
|
|
|
Ammonia Vapor Compression with Secondary Loop
|
|
|
Acceptable |
Acceptable |
|
|
|
|
|
|
|
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
|
|
Chlorine
|
|
|
|
|
Acceptable |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Cryogenic Transport Refrigeration System
|
|
|
|
|
|
|
|
|
|
|
|
|
Acceptable |
|
|
|
|
|
|
|
Desiccant Cooling
|
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
|
|
Acceptable |
Acceptable |
|
|
|
|
|
|
|
|
|
Direct Nitrogen Expansion
|
|
|
|
|
Acceptable |
|
|
|
|
|
|
|
Acceptable |
|
|
|
|
|
|
|
Evaporative Cooling
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
|
|
Acceptable |
Acceptable |
|
|
|
|
|
|
|
|
|
FOR12A
|
|
|
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Acceptable |
Acceptable |
Acceptable |
Unacceptable in new equipment, as of January 1, 2021. |
|
Acceptable |
|
|
Acceptable |
Unacceptable |
Acceptable |
Acceptable |
Acceptable |
Unacceptable in new equipment as of January 1, 2019. |
|
Acceptable
|
FOR12B
|
|
|
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Acceptable |
Acceptable |
Acceptable |
Unacceptable in new equipment, as of January 1, 2021. |
|
Acceptable |
|
|
Acceptable |
Unacceptable |
Acceptable |
Acceptable |
Acceptable |
Unacceptable in new equipment as of January 1, 2019 |
|
Acceptable
|
Freeze 12
|
Unacceptable as of MY 2017. |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable
|
G2018C
|
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable |
|
|
|
Acceptable |
Acceptable |
|
Acceptable |
Acceptable |
Acceptable |
|
Acceptable
|
GHG-HP
|
Unacceptable as of MY 2017. |
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable
|
GHG-X5
|
Unacceptable as of MY 2017. |
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable
|
HC Blend A
|
|
|
|
|
Acceptable |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
HC Blend B
|
|
|
|
|
Acceptable |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
HCFC-123
|
|
|
Acceptable |
|
Acceptable |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
HCFC-124
|
|
|
Acceptable |
|
|
|
|
|
|
Acceptable |
|
|
|
|
|
|
|
|
|
|
HCFC-22
|
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable |
Acceptable |
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable
|
HCFC-22/HCFC-142b
|
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable
|
HCFO-1233zd(E)
|
|
|
|
|
Acceptable |
Acceptable |
|
|
Acceptable |
Acceptable |
|
|
|
|
|
|
|
|
|
|
HFC-134a
|
Unacceptable as of Model Year (MY) 2021, except where allowed under a narrowed use limit through MY 2025. Unacceptable for all newly manufactured vehicles as of MY 2026. |
Acceptable |
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit for military marine vessels and human-rated spacecraft and related support equipment, as of January 1, 2024. |
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit for military marine vessels and human-rated spacecraft and related support equipment, as of January 1, 2024. |
Acceptable |
Acceptable |
Acceptable |
Unacceptable in new equipment, as of January 1, 2021. |
Acceptable |
Acceptable, Applicable to new uses below 125 degrees F ambient |
Acceptable |
Acceptable |
Acceptable |
Unacceptable |
Acceptable |
Acceptable |
Acceptable |
Unacceptable in new equipment as of January 1, 2019. |
|
Acceptable
|
HFC-134a/HBr (92/8)
|
|
|
|
|
Acceptable |
Acceptable: Only acceptable for use as the primary heat transfer fluid in secondary-loop equipment for not-in-kind replacements. |
|
|
|
|
|
|
Acceptable |
Acceptable: Only acceptable for use as the primary heat transfer fluid in secondary-loop equipment for not-in-kind replacements. |
Acceptable: Only acceptable for use as the primary heat transfer fluid in secondary-loop equipment for not-in-kind replacements. |
Acceptable: Only acceptable for use as the primary heat transfer fluid in secondary-loop equipment for not-in-kind replacements. |
Acceptable: Only acceptable for use as the primary heat transfer fluid in secondary-loop equipment for not-in-kind replacements. |
|
|
|
HFC-152a
|
Acceptable with Use Conditions |
|
|
|
|
|
|
Acceptable |
|
|
|
|
|
|
|
|
|
|
|
|
HFC-227ea
|
|
|
Unacceptable, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Acceptable with Use Conditions: When manufactured using any process that does not convert perfluoroisobutylene (PFIB) directly to HFC-236fa in a single step. |
Unacceptable in new equipment as of January 1, 2023. |
|
|
|
|
|
|
|
Unacceptable |
Unacceptable in new equipment as of January 1, 2021. |
Unacceptable in new equipment as of January 1, 2017 |
Unacceptable in new equipment as of January 1, 2017 |
|
|
|
HFC-23
|
|
|
|
|
Acceptable |
|
|
|
|
|
|
|
|
|
|
|
|
|
Acceptable |
|
HFC-32
|
|
|
|
|
|
|
|
|
|
|
Acceptable with Use Conditions |
|
|
|
|
|
|
|
|
|
HFC-236fa
|
|
|
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
|
Acceptable |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
HFC-245fa
|
|
|
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
|
Acceptable |
|
|
|
|
Acceptable |
|
|
|
|
|
|
|
|
Acceptable |
|
HFE-347mcc3 (heptafluoropropyl methyl ether)
|
|
|
|
|
Acceptable |
|
|
|
|
|
|
|
|
|
|
|
|
|
Acceptable |
|
HFE-449s1 (methoxynonafluorobutane, iso and normal)
|
|
|
|
|
Acceptable: Only acceptable for use as a secondary heat transfer fluid in not-in-kind systems. |
|
|
|
|
|
|
|
|
Acceptable: Only acceptable for use as a secondary heat transfer fluid in not-in-kind systems. |
Acceptable: Only acceptable for use as a secondary heat transfer fluid in not-in-kind systems. |
Acceptable: Only acceptable for use as a secondary heat transfer fluid in not-in-kind systems. |
Acceptable: Only acceptable for use as the primary heat transfer fluid in secondary-loop equipment for not-in-kind replacements. |
|
Acceptable: Only acceptable for use as a secondary heat transfer fluid in not-in-kind systems. |
|
HFE-569sf2 (ethoxynonafluorobutane, iso and normal)
|
|
|
|
|
Acceptable: Only acceptable for use as a secondary heat transfer fluid in not-in-kind systems. |
|
|
|
|
|
|
|
|
Acceptable: Only acceptable for use as a secondary heat transfer fluid in not-in-kind systems. |
|
Acceptable: Only acceptable for use as a secondary heat transfer fluid in not-in-kind systems. |
Acceptable: Only acceptable for use as the primary heat transfer fluid in secondary-loop equipment for not-in-kind replacements. |
|
Acceptable: Only acceptable for use as a secondary heat transfer fluid in not-in-kind systems. |
|
HFO-1234ze
|
|
|
Acceptable |
Acceptable |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
HFO-1336mzz(Z) ((Z)-1,1,1,4,4,4-hexafluorobut-2-ene)
|
|
|
Acceptable |
Acceptable |
|
|
|
|
|
Acceptable |
|
|
|
|
|
|
|
|
|
|
HFO-1336mzz(Z)/dichloroethylene blend (R-514A)
|
|
|
Acceptable |
Acceptable |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Ikon A
|
Acceptable with Use Conditions |
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable |
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable
|
Ikon B
|
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable |
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable
|
ISCEON 89
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Acceptable |
|
NARM-502
|
|
|
|
|
Acceptable |
|
|
|
|
|
|
|
|
|
|
|
|
|
Acceptable |
|
Pressure stepdown
|
|
|
|
|
|
Acceptable |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
R-1224yd(Z)
|
|
|
Acceptable |
Acceptable |
Acceptable |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
R-125/R-134a/R-600a (28.1/70.0/1.9)
|
|
Acceptable |
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Acceptable |
|
|
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
|
|
|
|
Acceptable |
|
R-125/R-290/R-134a/R-600a (55.0/1.0/42.5/1.5)
|
|
|
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Acceptable |
Unacceptable in new equipment as of January 1, 2023. |
Acceptable |
Unacceptable in new equipment, as of January 1, 2021. |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Unacceptable |
Unacceptable in new equipment as of January 1, 2021. |
Acceptable |
Acceptable |
Unacceptable in new equipment as of January 1, 2019 |
|
Acceptable
|
R-170 (Ethane)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Acceptable with Use Conditions |
|
R-1270 (Propylene)
|
|
|
Unacceptable as of January 3, 2017. |
Unacceptable as of January 3, 2017. |
Acceptable |
Unacceptable, as of January 3, 2017. |
|
|
|
|
Unacceptable, as of January 3, 2017. |
|
|
|
|
|
|
|
|
|
R-290 (Propane)
|
|
|
|
|
Acceptable |
|
Acceptable with Use Conditions |
Acceptable with Use Conditions |
|
|
Acceptable with Use Conditions: For use in self-contained room air conditioningee rule for detailed conditions |
|
|
Acceptable with Use Conditions |
|
|
|
Acceptable with Use Conditions |
Acceptable with Use Conditions |
Acceptable with Use Conditions
|
R-401A
|
|
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable
|
R-401B
|
|
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable
|
R-402A
|
|
|
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
|
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
|
|
R-402B
|
|
|
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
|
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
|
|
R-403B
|
|
|
|
|
Acceptable |
|
|
|
|
|
|
|
|
|
|
|
|
|
Acceptable |
|
R-404A
|
|
|
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit for human-rated spacecraft and related support equipment, as of January 1, 2024. |
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit for human-rated spacecraft and related support equipment, as of January 1, 2024. |
Acceptable |
Unacceptable in new equipment as of January 1, 2023. |
Acceptable |
Unacceptable in new equipment, as of January 1, 2021. |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Unacceptable |
Unacceptable in new equipment as of January 1, 2021. |
Unacceptable in retrofit equipment as of July 20, 2016.Unacceptable in new equipment as of January 1, 2018 |
Unacceptable in retrofit equipment as of July 20, 2016. Unacceptable in new equipment as of January 1, 2017. |
Unacceptable in retrofit equipment as of July 20, 2016.Unacceptable in new equipment as of January 1, 2019. |
Acceptable |
Acceptable
|
R-406A
|
Unacceptable as of MY 2017 |
|
Acceptable |
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable
|
R-407A
|
|
|
|
|
Acceptable |
Unacceptable in new equipment as of January 1, 2023. |
Acceptable |
Unacceptable in new equipment, as of January 1, 2021. |
Acceptable |
|
Acceptable |
|
Acceptable |
Unacceptable |
Unacceptable in new equipment as of January 1, 2021. |
Acceptable |
Acceptable |
|
|
|
R-407B
|
|
|
|
|
Acceptable |
Unacceptable in new equipment as of January 1, 2023. |
Acceptable |
|
Acceptable |
|
|
|
Acceptable |
Unacceptable |
Unacceptable in new equipment as of January 1, 2021. |
Unacceptable in retrofit equipment as of July 20, 2016.Unacceptable in new equipment as of January 1, 2018 |
Unacceptable in retrofit equipment as of July 20, 2016. Unacceptable in new equipment as of January 1, 2017. |
|
|
|
R-407C
|
|
Acceptable |
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Unacceptable |
Unacceptable in new equipment as of January 1, 2021. |
Acceptable |
Acceptable |
Unacceptable in new equipment as of January 1, 2019. |
Acceptable |
Acceptable
|
R-407D
|
|
|
|
|
|
|
|
|
|
|
|
|
Acceptable |
|
|
|
|
|
|
|
R-407F
|
|
Acceptable |
|
|
Acceptable |
Acceptable |
Acceptable |
Unacceptable in new equipment, as of January 1, 2021. |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable |
Unacceptable |
Unacceptable in new equipment as of January 1, 2021. |
Acceptable |
Acceptable |
|
|
|
R-407H
|
|
|
|
|
|
|
|
|
|
|
|
|
Acceptable: For use in refrigerated trucks and trailers only |
|
Acceptable |
Acceptable |
Acceptable |
|
|
|
R-408A
|
|
|
|
|
Acceptable |
Acceptable |
Acceptable |
|
|
|
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
|
|
R-409A
|
|
|
|
|
|
|
Acceptable |
Acceptable |
|
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable
|
R-410A
|
|
Acceptable |
Unacceptable, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Acceptable |
Unacceptable in new equipment as of January 1, 2023. |
Acceptable |
Unacceptable in new equipment, as of January 1, 2021. |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Unacceptable |
Unacceptable in new equipment as of January 1, 2021. |
Acceptable |
Acceptable |
Unacceptable in new equipment as of January 1, 2019 |
Acceptable |
Acceptable
|
R-410B
|
|
|
Unacceptable, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Acceptable |
Unacceptable in new equipment as of January 1, 2023. |
Acceptable |
Unacceptable in new equipment, as of January 1, 2021. |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Unacceptable |
Unacceptable in new equipment as of January 1, 2021. |
Acceptable |
Acceptable |
Unacceptable in new equipment as of January 1, 2019 |
Acceptable |
Acceptable
|
R-411A
|
|
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
|
|
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable
|
R-411B
|
|
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
|
|
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable
|
R-414A
|
Unacceptable as of MY 2017. |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable
|
R-414B
|
Unacceptable as of MY 2017. |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable |
Acceptable |
Acceptable |
|
Acceptable |
Acceptable |
Acceptable |
|
Acceptable
|
R-416A
|
Unacceptable as of MY 2017. |
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
|
|
Acceptable |
Acceptable |
Acceptable |
|
Acceptable |
Acceptable |
Acceptable |
|
Acceptable
|
R-417A
|
|
Acceptable |
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Acceptable |
Unacceptable in new equipment as of January 1, 2023. |
Acceptable |
Unacceptable in new equipment, as of January 1, 2021. |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable |
Unacceptable |
Unacceptable in new equipment as of January 1, 2021. |
Acceptable |
Acceptable |
Unacceptable in new equipment as of January 1, 2019 |
|
Acceptable
|
R-417C
|
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable |
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
|
R-420A
|
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable |
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable
|
R-421A
|
|
|
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Acceptable |
Unacceptable in new equipment as of January 1, 2023. |
Acceptable |
Unacceptable in new equipment, as of January 1, 2021. |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Unacceptable |
Unacceptable in new equipment as of January 1, 2021. |
Acceptable |
Acceptable |
Unacceptable in new equipment as of January 1, 2019 |
|
Acceptable
|
R-421B
|
|
|
|
|
Acceptable |
Unacceptable in new equipment as of January 1, 2023. |
Acceptable |
Unacceptable in new equipment, as of January 1, 2021. |
Acceptable |
Acceptable |
|
|
Acceptable |
Unacceptable |
Unacceptable in new equipment as of January 1, 2021. |
Unacceptable in retrofit equipment as of July 20, 2016.Unacceptable in new equipment as of January 1, 2018 |
Unacceptable in retrofit equipment as of July 20, 2016. Unacceptable in new equipment as of January 1, 2017. |
|
|
Acceptable
|
R-422A
|
|
|
|
|
Acceptable |
Unacceptable in new equipment as of January 1, 2023. |
Acceptable |
Unacceptable in new equipment, as of January 1, 2021. |
Acceptable |
|
|
|
Acceptable |
Unacceptable |
Unacceptable in new equipment as of January 1, 2021. |
Unacceptable in retrofit equipment as of July 20, 2016.Unacceptable in new equipment as of January 1, 2018 |
Unacceptable in retrofit equipment as of July 20, 2016. Unacceptable in new equipment as of January 1, 2017. |
|
|
|
R-422B
|
|
Acceptable |
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Acceptable |
Unacceptable in new equipment as of January 1, 2023. |
Acceptable |
Unacceptable in new equipment, as of January 1, 2021. |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Unacceptable |
Unacceptable in new equipment as of January 1, 2021. |
Acceptable |
Acceptable |
|
Acceptable |
|
R-422C
|
|
|
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Acceptable |
Unacceptable in new equipment as of January 1, 2023. |
Acceptable |
Unacceptable in new equipment, as of January 1, 2021. |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Unacceptable |
Unacceptable in new equipment as of January 1, 2021. |
Unacceptable in retrofit equipment as of July 20, 2016.Unacceptable in new equipment as of January 1, 2018 |
Unacceptable in retrofit equipment as of July 20, 2016. Unacceptable in new equipment as of January 1, 2017. |
Unacceptable in new equipment as of January 1, 2019 |
Acceptable |
Acceptable
|
R-422D
|
|
Acceptable |
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Acceptable |
Unacceptable in new equipment as of January 1, 2023. |
Acceptable |
Unacceptable in new equipment, as of January 1, 2021. |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Unacceptable |
Unacceptable in new equipment as of January 1, 2021. |
Unacceptable in retrofit equipment as of July 20, 2016.Unacceptable in new equipment as of January 1, 2018 |
Unacceptable in retrofit equipment as of July 20, 2016. Unacceptable in new equipment as of January 1, 2017. |
Unacceptable in new equipment as of January 1, 2019 |
|
Acceptable
|
R-423A
|
|
|
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
|
Acceptable |
Unacceptable in new equipment as of January 1, 2023. |
|
|
Acceptable |
Acceptable |
|
|
|
|
|
|
|
|
|
|
R-424A
|
|
Acceptable |
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Acceptable |
Unacceptable in new equipment as of January 1, 2023. |
Acceptable |
Unacceptable in new equipment, as of January 1, 2021. |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Unacceptable |
Unacceptable in new equipment as of January 1, 2021. |
Acceptable |
Acceptable |
|
|
|
R-426A
|
Unacceptable as of MY 2017. |
Acceptable |
|
|
Acceptable |
Acceptable |
Acceptable |
Unacceptable in new equipment, as of January 1, 2021. |
Acceptable |
Acceptable |
|
Acceptable |
Acceptable |
Unacceptable |
Acceptable |
Acceptable |
Acceptable |
Unacceptable in new equipment as of January 1, 2019 |
|
Acceptable
|
R-427A
|
|
Acceptable |
|
Acceptable |
Acceptable |
|
|
Acceptable |
|
Acceptable |
Acceptable |
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
|
|
R-428A
|
|
|
|
|
Acceptable |
Unacceptable in new equipment as of January 1, 2023. |
Acceptable |
Unacceptable in new equipment, as of January 1, 2021. |
Acceptable |
|
|
|
Acceptable |
Unacceptable |
Unacceptable in new equipment as of January 1, 2021. |
Unacceptable in retrofit equipment as of July 20, 2016.Unacceptable in new equipment as of January 1, 2018 |
Unacceptable in retrofit equipment as of July 20, 2016. Unacceptable in new equipment as of January 1, 2017. |
|
|
|
R-434A
|
|
Acceptable |
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Acceptable |
Unacceptable in new equipment as of January 1, 2023. |
Acceptable |
Unacceptable in new equipment, as of January 1, 2021. |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Unacceptable |
Unacceptable in new equipment as of January 1, 2021. |
Unacceptable in retrofit equipment as of July 20, 2016.Unacceptable in new equipment as of January 1, 2018 |
Unacceptable in retrofit equipment as of July 20, 2016. Unacceptable in new equipment as of January 1, 2017. |
|
|
Acceptable
|
R-437A
|
|
|
|
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Acceptable |
Acceptable |
Acceptable |
Unacceptable in new equipment, as of January 1, 2021. |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Unacceptable |
Unacceptable in new equipment as of January 1, 2021. |
Acceptable |
Acceptable |
Unacceptable in new equipment as of January 1, 2019 |
|
Acceptable
|
R-438A
|
|
Acceptable |
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Acceptable |
Unacceptable in new equipment as of January 1, 2023. |
Acceptable |
Unacceptable in new equipment, as of January 1, 2021. |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Unacceptable |
Unacceptable in new equipment as of January 1, 2021. |
Acceptable |
Acceptable |
Unacceptable in new equipment as of January 1, 2019 |
|
Acceptable
|
R-441A
|
|
|
|
|
|
|
|
Acceptable with Use Conditions |
|
|
Acceptable with Use Conditions: For use in self-contained room air conditioning |
|
|
Acceptable with Use Conditions |
|
|
|
Acceptable with Use Conditions |
|
|
R-442A
|
|
|
|
|
|
|
Acceptable |
|
Acceptable |
|
|
|
|
|
|
Acceptable |
Acceptable |
|
|
|
R-443A
|
|
|
Unacceptable as of January 3, 2017. |
Unacceptable as of January 3, 2017. |
|
Unacceptable, as of January 3, 2017. |
|
|
|
|
Unacceptable, as of January 3, 2017. |
|
|
|
|
|
|
|
|
|
R-448A
|
|
|
|
|
Acceptable |
Acceptable |
Acceptable |
|
Acceptable |
|
|
|
Acceptable |
Acceptable: Low temperature Use |
Acceptable |
Acceptable |
Acceptable |
|
|
|
R-449A
|
|
|
|
|
Acceptable |
Acceptable |
Acceptable |
|
Acceptable |
|
|
|
Acceptable |
Acceptable: Low temperature Use |
Acceptable |
Acceptable |
Acceptable |
|
|
|
R-449B
|
|
|
|
|
Acceptable |
Acceptable |
Acceptable |
|
Acceptable |
|
|
|
Acceptable |
Acceptable: Low temperature Use |
Acceptable |
Acceptable |
Acceptable |
|
|
|
R-450A
|
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable
|
R-452A
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Acceptable |
|
|
|
|
R-452B
|
|
|
|
|
|
|
|
|
|
|
Acceptable with Use Conditions |
|
Acceptable: For use in refrigerated trucks and trailers only. |
|
|
|
|
|
|
|
R-452C
|
|
|
|
|
|
|
|
|
|
|
|
|
Acceptable: For use in refrigerated trucks and trailers only. |
|
|
Acceptable |
|
|
|
|
R-453A
|
|
|
|
|
Acceptable |
Acceptable |
|
|
|
|
|
|
Acceptable: For use in refrigerated trucks and trailers only. |
|
|
Acceptable |
|
|
|
|
R-454A
|
|
|
|
|
|
|
|
|
|
|
Acceptable with Use Conditions |
|
|
|
|
|
|
|
|
|
R-454B
|
|
|
|
|
|
|
|
|
|
|
Acceptable with Use Conditions |
|
|
|
|
|
|
|
|
|
R-454C
|
|
|
|
|
|
|
|
|
|
|
Acceptable with Use Conditions |
|
|
|
|
|
|
|
|
|
R-457A
|
|
|
|
|
|
|
|
|
|
|
Acceptable with Use Conditions |
|
|
|
|
|
|
|
|
|
R-458A
|
|
|
|
|
Acceptable |
|
|
|
|
|
Acceptable |
|
|
|
|
Acceptable |
|
|
|
|
R-507, R-507A
|
|
|
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Acceptable |
Unacceptable in new equipment as of January 1, 2023. |
Acceptable |
Unacceptable in new equipment, as of January 1, 2021. |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Unacceptable |
Unacceptable in new equipment as of January 1, 2021. |
Unacceptable in retrofit equipment as of July 20, 2016.Unacceptable in new equipment as of January 1, 2018 |
Unacceptable in retrofit equipment as of July 20, 2016. Unacceptable in new equipment as of January 1, 2017. |
Unacceptable in retrofit equipment as of July 20, 2016.Unacceptable in new equipment as of January 1, 2019. |
Acceptable |
Acceptable
|
R-508A
|
|
|
|
|
Acceptable |
|
|
|
|
|
|
|
|
|
|
|
|
|
Acceptable |
|
R-508B
|
|
|
|
|
Acceptable |
|
|
|
|
|
|
|
|
|
|
|
|
|
Acceptable |
|
R-513A
|
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable |
Acceptable |
Acceptable with Use Conditions: Low temperature |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable
|
R-515B
|
|
|
Acceptable |
Acceptable |
|
|
|
|
|
Acceptable |
|
|
|
|
|
|
|
|
|
|
R-600 (Butane)
|
|
|
|
|
Acceptable |
|
|
Acceptable with Use Conditions |
|
|
|
|
|
Acceptable with Use Conditions |
|
|
|
Acceptable with Use Conditions |
|
|
R-744 (Carbon Dioxide, CO2)
|
Acceptable with Use Conditions |
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
|
Acceptable |
Acceptable |
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
RB-276
|
Unacceptable as of MY 2017. |
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable
|
RS-24 (2002 formulation)
|
Acceptable with Use Conditions |
Acceptable |
|
|
Acceptable |
Acceptable |
Acceptable |
Unacceptable in new equipment, as of January 1, 2021. |
Acceptable |
Acceptable |
|
Acceptable |
Acceptable |
Unacceptable |
Acceptable |
Acceptable |
Acceptable |
Unacceptable in new equipment as of January 1, 2019 |
|
Acceptable
|
RS-44 (2003 formulation)
|
|
|
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Acceptable |
Unacceptable in new equipment as of January 1, 2023. |
Acceptable |
Unacceptable in new equipment, as of January 1, 2021. |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Unacceptable |
Unacceptable in new equipment as of January 1, 2021. |
Acceptable |
Acceptable |
|
|
|
Self-chilling cans using CO2
|
|
|
|
|
|
Acceptable |
|
Acceptable |
|
|
|
|
Acceptable |
Acceptable |
|
Acceptable |
Acceptable |
Acceptable |
|
|
SP34E
|
Unacceptable as of MY 2017. |
Acceptable |
|
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Acceptable |
Acceptable |
|
Unacceptable in new equipment, as of January 1, 2021. |
|
|
|
|
Acceptable |
Unacceptable |
Acceptable |
Acceptable |
Acceptable |
Unacceptable in new equipment as of January 1, 2019 |
|
Acceptable
|
Stirling Cycle
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
|
|
|
|
Acceptable |
|
|
|
|
Acceptable |
|
|
THR-01
|
|
|
|
|
|
|
|
Acceptable |
|
|
|
|
|
|
|
|
|
|
|
|
THR-02
|
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable |
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable
|
THR-03
|
|
|
Unacceptable, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Unacceptable in new equipment, except as otherwise allowed under a narrowed use limit, as of January 1, 2024. |
Acceptable |
Acceptable |
Acceptable |
Unacceptable in new equipment, as of January 1, 2021. |
Acceptable |
Acceptable |
Acceptable with Use Conditions: For use in residential window unit air conditioning. |
|
Acceptable |
Unacceptable |
Acceptable |
Acceptable |
Acceptable |
|
|
|
THR-04
|
|
|
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
|
|
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
Acceptable |
|
Acceptable
|
Trans-1-chloro-3,3,3-trifluoroprop-1-ene
|
|
|
Acceptable |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Water / Lithium Bromide Absorption
|
|
|
Acceptable |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|