Electronic color code

A 2.26 , 1%-precision resistor with 5 color bands (E96 series), from top, 2-2-6-1-1; the last two brown bands indicate the multiplier (×10) and the tolerance (1%).

An electronic color code or electronic colour code (see spelling differences) is used to indicate the values or ratings of electronic components, usually for resistors, but also for capacitors, inductors, diodes and others. A separate code, the 25-pair color code, is used to identify wires in some telecommunications cables. Different codes are used for wire leads on devices such as transformers or in building wiring.

History

RMA resistor color code guide, ca. 1945–1950

Before industry standards were established, each manufacturer used its own unique system for color coding or marking their components.

In the 1920s,[citation needed] the RMA resistor color code was developed by the Radio Manufacturers Association (RMA) as a fixed resistor coloring code marking. In 1930, the first radios with RMA color-coded resistors were built.[1][2] Over many decades, as the organization name changed (RMA, RTMA, RETMA, EIA)[3] so was the name of the code. Though known most recently as EIA color code, the four name variations are found in books, magazines, catalogs, and other documents over more than 94 years.

In 1952, it was standardized in IEC 62:1952 by the International Electrotechnical Commission (IEC) and since 1963 also published as EIA RS-279.[4] Originally only meant to be used for fixed resistors, the color code was extended to also cover capacitors with IEC 62:1968. The code was adopted by many national standards like DIN 40825 (1973), BS 1852 (1974) and IS 8186 (1976). The current international standard defining marking codes for resistors and capacitors is IEC 60062:2016.[5] In addition to the color code, these standards define a letter and digit code named RKM code for resistors and capacitors.

Color bands were used because they were easily and cheaply printed on tiny components. However, there were drawbacks, especially for color blind people. Overheating of a component or dirt accumulation may make it impossible to distinguish brown from red or orange. Advances in printing technology have now made printed numbers more practical on small components. The values of components in surface mount packages are marked with printed alphanumeric codes instead of a color code.

Resistors

One decade of the E12 series (there are twelve preferred values per decade of values) shown with their electronic color codes on resistors
A 0 Ω resistor (zero ohm), marked with a single black band

Color band system

To distinguish left from right there is a gap between the C and D bands: A diagram of a resistor, with four color bands A, B, C, D from left to right A diagram of a 2.7 MΩ color-coded resistor.

  1. The first significant figure of component value (left side)
  2. The second significant figure (some precision resistors have a third significant figure, and thus five bands).
  3. The decimal multiplier (number of trailing zeroes, or power of 10 multiplier)
  4. If present, indicates tolerance of value in percent (no band means 20%)

In the above example, a resistor with bands of red, violet, green, and gold has first digit 2 (red; see table below), second digit 7 (violet), followed by 5 (green) zeroes: 2700000 ohms. Gold signifies that the tolerance is ±5%.

Precision resistors may be marked with a five band system, to include three significant digits, a power of 10 multiplier (number of trailing zeroes, and a tolerance band. An extra-wide first band indicates a wire-wound resistor.[6]

resistor color code
Resistor color code

Resistors manufactured for military use may also include a fifth band which indicates component failure rate (reliability); refer to MIL-HDBK-199[7] for further details.

Tight tolerance resistors may have three bands for significant figures rather than two, or an additional band indicating temperature coefficient of resistance (TCR), in units of ppm/K.

All coded components have at least two value bands and a multiplier; other bands are optional.

The standard color code per IEC 60062:2016 is as follows:

Ring color Significant figures Multiplier Tolerance Temperature coefficient
Name Code RAL[nb 1] Percent [%] Letter [ppm/K] Letter
None ±20 M
Pink PK 3015 ×10−3[8] ×0.001
Silver SR ×10−2 ×0.01 ±10 K
Gold GD ×10−1 ×0.1 ±5 J
Black BK 9005 0 ×100 ×1 250 U
Brown BN 8003 1 ×101 ×10 ±1 F 100 S
Red RD 3000 2 ×102 ×100 ±2 G 50 R
Orange OG 2003 3 ×103 ×1000 ±0.05[8] W 15 P
Yellow YE 1021 4 ×104 ×10000 ±0.02[8][nb 2][9] P 25 Q
Green GN 6018 5 ×105 ×100000 ±0.5 D 20 Z[nb 3]
Blue BU 5015 6 ×106 ×1000000 ±0.25 C 10 Z[nb 3]
Violet VT 4005 7 ×107 ×10000000 ±0.1 B 5 M
Gray GY 7000 8 ×108 ×100000000 ±0.01[8][nb 4][nb 2][9] L (A) 1 K
White WH 1013 9 ×109 ×1000000000

Resistors use various E series of preferred numbers for their specific values, which are determined by their tolerance. These values repeat for every decade of magnitude: ... 0.68, 6.8, 68, 680, ... For resistors of 20% tolerance the E6 series, with six values: 10, 15, 22, 33, 47, 68, then 100, 150, ... is used; each value is approximately the previous value multiplied by 610. For 10% tolerance resistors the E12 series, with 1210 as multiplier, is used; similar schemes up to E192, for 0.5% or tighter tolerance are used. The separation between the values is related to the tolerance so that adjacent values at the extremes of tolerance approximately just overlap; for example, in the E6 series 10 + 20% is 12, while 15 − 20% is also 12.

Zero ohm resistors, marked with a single black band,[10] are lengths of wire wrapped in a resistor-like body which can be mounted on a printed-circuit board (PCB) by automatic component-insertion equipment. They are typically used on PCBs as insulating "bridges" where two tracks would otherwise cross, or as soldered-in jumper wires for setting configurations.

Body-end-dot system

The "body-end-dot" or "body-tip-spot" system was used for cylindrical composition resistors sometimes still found in very old equipment (built before the Second World War); the first band was given by the body color, the second band by the color of one end of the resistor, and the multiplier by a dot or band around the middle of the resistor. The other end of the resistor was in the body color, silver, or gold for 20%, 10%, 5% tolerance (tighter tolerances were not routinely used).[11][12][13][14]

Examples

Example color-coded resistors

From top to bottom:

  • Green, blue, black, black, brown
    • 560 ohms ±1%
  • Red, red, orange, gold
    • 22000 ohms ±5%
  • Yellow, violet, brown, gold
    • 470 ohms ±5%
  • Blue, grey, black, gold
    • 68 ohms ±5%

The physical size of a resistor is indicative of the power it can dissipate.

There is an important difference between the use of three and of four bands to indicate resistance. The same resistance is encoded by:

  • Red, red, orange = 22 followed by 3 zeroes = 22000 (excluding default, silver, or gold tolerance)
  • Red, red, black, red = 220 followed by 2 zeroes = 22000 (excluding brown or other band for tolerance)

Mnemonics

Useful mnemonics have been created to make it easier to remember the numeric order of resistor color bands:

  • Betty Brown Runs Over Your Garden But Violet Gingerly Walks.
  • Bad Bears Raid Our Yummy Grub But Veto Grey Waffles.
  • BB ROY from Great Britain has a Very Good Wife.

The following example includes the tolerance codes — gold, silver and none:

  • Bad Beer Rots Out Your Guts But Vodka Goes Well – Get Some Now.[15]

The colors are sorted in ascending order of frequency to make them easy to remember and to reduce the significance of possible read errors due to color shifts and fading over time: red (2), orange (3), yellow (4), green (5), blue (6), violet (7). Black (0) has no energy, brown (1) has a little more, white (9) has everything and grey (8) is like white, but less intense.[16]

Capacitors

Capacitors may be marked with 4 or more colored bands or dots. The colors encode the first and second most significant digits of the value in picofarads, and the third color the decimal multiplier. Additional bands have meanings which may vary from one type to another. Low-tolerance capacitors may begin with the first 3 (rather than 2) digits of the value. It is usually, but not always, possible to work out what scheme is used by the particular colors used. Cylindrical capacitors marked with bands may look like resistors.

Color Significant digits Multiplier Tolerance [%] Characteristic DC working voltage [V] Operating temperature [°C] EIA/vibration [Hz]
  Black 0 1 −55 to +70 10 to 55
Brown 1 10 ±1 B 100
Red 2 100 ±2 C −55 to +85
Orange 3 1000 D 300
Yellow 4 10000 E −55 to +125 10 to 2000
Green 5 100000 ±0.5 F 500
Blue 6 1000000 −55 to +150
Violet 7 10000000
Grey 8
White 9 EIA
Gold ±5[nb 5] 1000
Silver ±10

Extra bands on ceramic capacitors identify the voltage rating class and temperature coefficient characteristics.[11] A broad black band was applied to some tubular paper capacitors to indicate the end that had the outer electrode; this allowed this end to be connected to chassis ground to provide some shielding against hum and noise pickup.

Polyester film and "gum drop" tantalum electrolytic capacitors may also be color-coded to give the value, working voltage and tolerance.

Postage stamp capacitors and war standard coding

Postage-stamp mica capacitors marked with the EIA 3-dot and 6-dot color codes, giving capacitance value, tolerance, working voltage, and temperature characteristic. This style of capacitor was used in vacuum-tube equipment.

Capacitors of the rectangular "postage stamp" form made for military use during World War II used American War Standard (AWS) or Joint Army-Navy (JAN) coding in six dots stamped on the capacitor. An arrow on the top row of dots pointed to the right, indicating the reading order. From left to right the top dots were: either black, indicating JAN mica, or silver, indicating AWS paper; first significant digit; and second significant digit. The bottom three dots indicated temperature characteristic, tolerance, and decimal multiplier. The characteristic was black for ±1000 ppm/°C, brown for ±500, red for ±200, orange for ±100, yellow for −20 to +100 ppm/°C, and green for 0 to +70 ppm/°C.

A similar six-dot code by EIA had the top row as first, second and third significant digits and the bottom row as voltage rating (in hundreds of volts; no color indicated 500 volts), tolerance, and multiplier. A three-dot EIA code was used for 500 volt 20% tolerance capacitors, and the dots signified first and second significant digits and the multiplier. Such capacitors were common in vacuum tube equipment and in surplus for a generation after the war but are unavailable now.[17]

Inductors

Standards IEC 60062 / EN 60062 do not define a color code for inductors, but manufacturers of small inductors use the resistor color code, typically encoding inductance in microhenries.[18] A white tolerance ring is used by TDK to indicate custom specifications.[18]

Diodes

The part number for small JEDEC "1N"-coded diodes – in the form "1N4148" – is sometimes encoded as three or four rings in the standard color code, omitting the "1N" prefix. The 1N4148 would then be coded as yellow (4), brown (1), yellow (4), grey (8).

Wire

Transformer

Power transformers used in North American vacuum-tube equipment were often color-coded to identify the leads. Black was the primary connection, red secondary for the B+ (plate voltage), red with a yellow tracer was the center tap for the B+ full-wave rectifier winding, green or brown was the heater voltage for all tubes, yellow was the filament voltage for the rectifier tube (often a different voltage than other tube heaters). Two wires of each color were provided for each circuit, and phasing was not identified by the color code.

Audio transformers for vacuum tube equipment were coded blue for the finishing lead of the primary, red for the B+ lead of the primary, brown for a primary center tap, green for the finishing lead of the secondary, black for grid lead of the secondary, and yellow for a tapped secondary. Each lead had a different color since relative polarity or phase was more important for these transformers. Intermediate-frequency tuned transformers were coded blue and red for the primary and green and black for the secondary.[17]

Other

Wires may be color-coded to identify their function, voltage class, polarity, phase or to identify the circuit in which they are used. The insulation of the wire may be solidly colored, or where more combinations are needed, one or two tracer stripes may be added. Some wiring color codes are set by national regulations, but often a color code is specific to a manufacturer or industry.

Building wiring under the US National Electrical Code and the Canadian Electrical Code is identified by colors to show energized, neutral, and grounding conductors, and to identify phases. Other color codes are used in the UK and other areas to identify building wiring or flexible cable wiring.

Mains electrical wiring, both in a building and on equipment, was once usually red for live, black for neutral, and green for earth, but this was changed as it was a hazard for color-blind people, who might confuse red and green; different countries use different conventions. Red and black are frequently used for positive and negative of battery or other single-voltage DC wiring.

Thermocouple wires and extension cables are identified by color code for the type of thermocouple; interchanging thermocouples with unsuitable extension wires destroys the accuracy of the measurement.

Automotive wiring is color-coded but standards vary by manufacturer; differing SAE and DIN standards exist.

Modern personal computer peripheral cables and connectors are color-coded to simplify connection of speakers, microphones, mice, keyboards and other peripherals, usually according to coloring schemes following recommendations such as PC System Design Guide, PoweredUSB, ATX, etc.

A common convention for wiring systems in industrial buildings is: black jacket – AC less than 1,000 volts, blue jacket – DC or communications, orange jacket – medium voltage 2,300 or 4,160 V, red jacket 13,800 V or higher. Red-jacketed cable is also used for relatively low-voltage fire alarm wiring, but has a much different appearance.

Local area network cables may also have non-standardised jacket colors identifying, for example, process control network vs. office automation networks, or to identify redundant network connections, but these codes vary by organization and facility.

See also

Notes

  1. ^ For illustration only. IEC 60062:2016 and IEC 60757:1982 do not specify or intend to specify color boundaries and properties, and colors shown here as example are applied for the purpose of consistent illustration only.
  2. ^ a b Before yellow and grey colored rings were assigned to tolerance values of ±0.02% and ±0.01% with IEC 60062:2016, some manufacturers used yellow and grey as substitute for gold (±5%) and silver (±10%) colored rings in high-voltage resistors to avoid metal particles in the lacquer.
  3. ^ a b Any temperature coefficient not assigned its own letter shall be marked "Z", and the coefficient found in other documentation.
  4. ^ Before a grey colored ring was assigned to a tolerance of ±0.01% with IEC 60062:2016, some manufacturers used a grey colored ring to indicate a non-standardized tolerance of ±0.05%.
  5. ^ ±5% or ±0.5 pF, whichever is greater.

References

  1. ^ Rider, John F.; Muhleman, M. L., eds. (April 1932). "Color coding" (PDF). Service - A Monthly Digest of Radio and Allied Maintenance. 1 (3). New York City, NY, USA: John F. Rider Publications, Inc.: 62. Retrieved 2019-11-15. Color coding of resistances used in receivers is not always according to the standard recommended by the RMA. Most of the manufacturers now are using this code. The following is a partial tabulation of receiver manufacturers and comments concerning their use of the body, tip and dot system. […] (NB. Part 1/2 of a list of when each radio manufacturer first started using RMA color coded resistors.)
  2. ^ Rider, John F.; Muhleman, M. L., eds. (May 1932). "Color coding - Continued from April issue" (PDF). Service - A Monthly Digest of Radio and Allied Maintenance. 1 (4). New York City, NY, USA: John F. Rider Publications, Inc.: 89. Retrieved 2019-11-15. (NB. Part 2/2 of a list of when each radio manufacturer first started using RMA color coded resistors.)
  3. ^ "JEDEC History". JEDEC. Archived from the original on 2007-09-29. Retrieved 2007-09-29.
  4. ^ EIA RS-279: Color code for film resistors. Electronic Industries Alliance. 1963-08-01.
  5. ^ "IEC 60062:2016-07" (6 ed.). July 2016. Archived from the original on 2018-07-23. Retrieved 2018-07-23. [1]
  6. ^ Westman, H. P., ed. (1968). Reference Data for Radio Engineers (5 ed.). ITT / Howard W. Sams. pp. 5-8–5-10. LCCN 43-14665.
  7. ^ "MIL-HDBK-199C" (PDF).
  8. ^ a b c d "IEC 60062:2016-07" (6 ed.). July 2016. Archived from the original on 2018-07-23. Retrieved 2018-07-23. [2]
  9. ^ a b VR37 High ohmic/high voltage resistors (PDF). Vishay. 2015. Archived from the original (PDF) on 2016-09-10.
  10. ^ "NZO series zero-ohm resistors". NIC Components Corp. Archived from the original on 2009-01-04.
  11. ^ a b Buttner, Harold H.; Kohlhaas, H. T.; Mann, F. J., eds. (1946). "Chapter 3: Audio and radio design". Reference Data for Radio Engineers (PDF) (2 ed.). Federal Telephone and Radio Corporation (FTR). pp. 52, 57. Archived (PDF) from the original on 2018-05-16. Retrieved 2020-01-03.
  12. ^ "How To Read Old Style Resistors" (PDF). 2006-10-03. Archived (PDF) from the original on 2016-12-19. Retrieved 2016-12-19.
  13. ^ "RMA Resistor and Flexible Resistor Color Codes". Archived from the original on 2016-12-19. Retrieved 2016-12-19.
  14. ^ "The Antique Resistor Color Code" (PDF). Archived (PDF) from the original on 2016-12-19. Retrieved 2016-12-19.
  15. ^ Campbell, Dean. "The Mnemonics Page". Bradley University Chemistry Department.
  16. ^ Clement, Preston R.; Johnson, Walter Curtis (1960). Electrical Engineering Science. McGraw-Hill. p. 115.
  17. ^ a b Dorbuck, Tony, ed. (1978) [1977]. The Radio Amateur's Handbook (5 ed.). Connecticut, USA: The American Radio Relay League. pp. 553–554. LCCN 41-3345. no ISBN.
  18. ^ a b "RF General" (PDF). TDK.
Online resistor calculators
Historical charts