Single-phase generator

Elementary generator is an example of single-phase generators with two poles

Single-phase generator (also known as single-phase alternator) is an alternating current electrical generator that produces a single, continuously alternating voltage. Single-phase generators can be used to generate power in single-phase electric power systems. However, polyphase generators are generally used to deliver power in three-phase distribution system and the current is converted to single-phase near the single-phase loads instead. Therefore, single-phase generators are found in applications that are most often used when the loads being driven are relatively light,[1] and not connected to a three-phase distribution, for instance, portable engine-generators. Larger single-phase generators are also used in special applications such as single-phase traction power for railway electrification systems.[2]

Designs

Revolving armature

The design of revolving armature generators is to have the armature part on a rotor and the magnetic field part on stator. A basic design, called elementary generator,[3] is to have a rectangular loop armature to cut the lines of force between the north and south poles. By cutting lines of force through rotation, it produces electric current. The current is sent out of the generator unit through two sets of slip rings and brushes, one of which is used for each end of the armature. In this two-pole design, as the armature rotates one revolution, it generates one cycle of single phase alternating current (AC). To generate an AC output, the armature is rotated at a constant speed having the number of rotations per second to match the desired frequency (in hertz) of the AC output.

The relationship of armature rotation and the AC output can be seen in this series of pictures. Due to the circular motion of the armature against the straight lines of force, a variable number of lines of force will be cut even at a constant speed of the motion. At zero degrees, the rectangular arm of the armature does not cut any lines of force, giving zero voltage output. As the armature arm rotates at a constant speed toward the 90° position, more lines are cut. The lines of force are cut at most when the armature is at the 90° position, giving out the most current on one direction. As it turns toward the 180° position, lesser number of lines of force are cut, giving out lesser voltage until it becomes zero again at the 180° position. The voltage starts to increase again as the armature heads to the opposite pole at the 270° position. Toward this position, the current is generated on the opposite direction, giving out the maximum voltage on the opposite side. The voltage decrease again as it completes the full rotation. In one rotation, the AC output is produced with one complete cycle as represented in the sine wave.

Armature of revolving armature single-phase generator with 4 windings and its output sine wave.
Single phase generator with four poles

More poles can also be added to single-phase generator to allow one rotation to produce more than one cycle of AC output. In an example on the left, the stator part is reconfigured to have 4 poles which are equally spaced. A north pole is adjacent to the two south poles. The shape of the armature at the rotor part is also changed. It is no longer a flat rectangle. The arm is bent 90 degrees. This allows one side of the armature to interact with a north pole while the other side interacts with a south pole similarly to the two-pole configuration. The current is still delivered out through the two sets of slip rings and brushes in the same fashion as in the two-pole configuration. The difference is that a cycle of AC output can be completed after a 180 degree rotation of the armature. In one rotation, the AC output will be two cycles. This increases the frequency of the output of the generator. More poles can be added to achieves higher frequency at the same rotation speed of the generator, or same frequency of output at the lower rotation speed of the generator depending on the applications.

This design also allows us to increase the output voltage by modifying the shape of the armature. We can add more rectangular loops to the armature as seen on the picture on the right. The additional loops at the armature arm are connected in series, which are actually additional windings of the same conductor wire to form a coil in rectangular shape. In this example, there are 4 windings in the coil. Since the shapes of all windings are the same, the amount of the lines of force will be cut at the same amount in the same direction at the same time in all windings. This creates in phase AC output for these 4 windings. As a result, the output voltage is increased 4 time as shown in the sine wave in the diagram.[4]

Revolving field

Diagram of revolving field single-phase generator with two poles
Diagram of revolving field single-phase generator with four poles

The design of revolving field generators is to have the armature part on stator and the magnetic field part on rotor. A basic design of revolving field single-phase generator is shown on the right. There are two magnetic poles, north and south, attached to a rotor and two coils which are connected in series and equally spaced on stator. The windings of the two coils are in reverse direction to have the current to flow in the same direction because the two coils always interact with opposing polarities. Since poles and coils are equally spaced and the locations of the poles match to the locations of the coils, the magnetic lines of force are cut at the same amount at any degree of the rotor. As a result, the voltages induced to all windings have the same value at any given time. The voltages from both coils are "in phase" to each other. Therefore, the total output voltage is two times the voltage induced in each winding. In the figure, at the position where pole number 1 and coil number 1 meet, the generator produces the highest output voltage on one direction. As the rotor turns 180 degrees, the output voltage is alternated to produce the highest voltage on the other direction.[3] The frequency of the AC output in this case equals to the number of rotations of the rotor per second.[1]

This design can also allow us to increase the output frequency by adding more poles. In this example on the right, we have 4 coils connected in series on the stator and the field rotor has 4 poles. Both coils and poles are equally spaced. Each pole has opposite polarity to its neighbors which are angled at 90 degrees. Each coils also have opposite winding to its neighbors. This configuration allows the lines of force at 4 poles to be cut by 4 coils at the same amount at a given time. At each 90-degree rotation, the voltage output polarity is switched from one direction to the other. Therefore, there are 4 cycles of the AC output in one rotation. As the 4 coils are wired in series and their outputs are "in phase", the AC output of this single-phase generator will have 4 times the voltage of that generated by each individual coil.[3]

A benefit of the revolving field design is that if the poles are permanent magnets, then there is no need to use any slip ring and brush to deliver electricity out of the generator as the coils are stationary and can be wired directly from the generator to the external loads.

Small generators

Single-phase generators that people are familiar with are usually small. The applications are for standby generators in case of main power supply is interrupted and for supplying temporary power on construction sites.[5]

Another application is in small wind technology. Although most of wind turbines use three-phase generators, single-phase generators are found in some of the small wind turbine models with rated power outputs of up with 55 kW. The single-phase models are available in the vertical axis wind turbines (VAWT) and Horizontal-axis wind turbines (HAWT).[6][7]

Power stations

In-conduit hydro turbine with single-phase generator at St. Louis Municipal Electric Power Plant in 1902
Pelton wheel on the left connected to single-phase generator on the right at Walchensee hydro station.
Single-phase generator driven by steam engine at St. Louis Municipal Electric Power Plant in 1902 (right)
Neckarwestheim Nuclear Power Plant

In the very early days of electricity generation, the generators at power stations had been single-phase AC or direct current. The direction of the power industry were changing in 1895 when more efficient polyphase generators were successfully implemented at Adams Hydroelectric Generating Plant which was the first large-scale polyphase power station.[8] Newer power stations started to adopt the polyphase system. In the 1900s, many railways started the electrification of their lines. During that time, the single-phase AC system had been widely used for their traction power networks beside the direct current system. The early generators for those single-phase traction networks are single-phase generators.[9] Even with newer three-phase motors which were introduced to some modern trains, the single-phases transmission for traction networks survive their time and are still in use in many railways today.[10] However, many traction power stations have replaced their generators over time to use three-phase generators and convert into single-phase for transmission.[11]

Hydro

In the early development of hydroelectricity, single-phase generators played an important role in demonstrating the benefits of alternating current. In 1891, a 3,000 volts and 133 Hz single-phase generator of 100 horsepower was installed at Ames Hydroelectric Generating Plant which was belt-connected with Pelton water wheel. The power was transmitted through 4.2 kilometres (2.6 mi) cables to power an identical motor at the mill. The plant was the first to generate alternating current electric power for industrial application and it was a demonstration of the efficiency in AC transmission. This was a precedent to larger for much larger plants such as the Edward Dean Adams Power Plant in Niagara Falls, New York in 1895.[12] However, the larger plants were operated using polyphase generators for greater efficiency. That left the applications for single-phase hydroelectricity generation to special cases such as in light loads.

An example of using single-phase in a special case was implemented in 1902 at St. Louis Municipal Electric Power Plant. A 20 kW single-phase generator was direct-connected to a Pelton water wheel to generate electricity enough to power light loads. This was an early demonstration of in-conduit hydro to capture energy from water flow in the public water pipeline. The energy for the water main in this case was not created by gravity, but the water was pumped by a larger steam engine at a water pumping station to supply water to customers. The decision to have water pumped by a larger engine then take some of the energy from water flow to power a smaller generator using water wheel was based on the cost. At the time, steam engines were not efficient and cost effective for a 20 kW system. Therefore, they installed a steam water pump to have enough energy to maintain water pressure for customer and to drive a small generator at the same time.[13]

The main usage of single-phase hydroelectricity generation today is to supply power for traction network for railways. Many electrical transmission networks for railways especially in Germany rely on single-phase generation and transmission which are still in use today. A notable power station is Walchensee Hydroelectric Power Station in Bavaria. The station takes water from elevated Lake Walchensee to drive eight turbines that drive the generators. Four of those are three-phase generators to supply the power grid. The other four are single-phase generators are connected to Pelton turbines which have combined capacity of 52 MW to supply the German 15 kV AC railway electrification.[14]

Similar single-phase hydroelectricity generations are also used in another variance of railway electrification system in the United States. A power station at Safe Harbor Dam in Pennsylvania provides power generation for both public utilities and for Amtrak railway. Two out of its 14 turbines are connected to two single-phase generators to supply Amtrak's 25 Hz traction power system. The two turbines are of Kaplan type with 5 blades rated 42,500 horsepower.[15]

Steam

In the early years, steam engines were used as prime movers of generators. An installation at St. Louis Municipal Electric Power Plant in the 1900s was an example of using steam engines with single-phase generators. The St. Louis plant used compound steam engine to drive a 100 kW single-phase generator which produced current at rated power of 1,150 volts.[13]

The steam engines were also used during the twentieth century in power stations for traction networks which had single-phase power distribution for specific railways. A special set of single-phase generators with steam turbines at Waterside Generating Station in New York City in 1938 was an example of such generation and distribution systems. The single-phase generators were eventually retired in the late 1970s due to concerns of a turbine failure in another station. The generators were replaced by two transformers to reduce from another three-phase power source to existing single-phase catenary power. Eventually, the transformers were replaced by two solid-state cycloconverter instead.[8]

Nuclear

Normally, nuclear power plants are used as base load stations with very high capacities to supply power to the grids. Neckarwestheim I in Neckarwestheim is a unique nuclear power plant in that it is equipped with high-capacity single-phase generators to supply Deutsche Bahn railway with specific AC voltage at frequency of 16 2/3 Hz. The pressurized water reactor transport thermal energy to two turbines and generators which are rated for 187 MW and 152 MW.[16]

See also

References

  1. ^ a b "Module 5—Introduction to Generators and Motors (NAVEDTRA 14177)" (PDF). Navy Electricity and Electronics Training Series. United States Navy. September 1998. pp. 3–7–3–8, 3–15. Retrieved 4 September 2013.
  2. ^ "Hydropower Sustainability Assessment Tool" (PDF). E.ON Kraftwerke GmbH. p. 2. Retrieved 4 September 2013.
  3. ^ a b c Aviation Maintenance Technician Handbook—General (FAA-H-8083-30) (PDF). Federal Aviation Administration. 2008. pp. 10–130, 10–161. Retrieved 6 September 2013.
  4. ^ "AC Motors and Generators". US Department of Defense. 1961. Retrieved 5 September 2013.
  5. ^ Brumbach, Michael E. (January 2010). Industrial electricity (8th ed.). Clifton Park, N.Y.: Delmar. p. 418. ISBN 9781435483743.
  6. ^ "Endurance E-3120-50 kW Wind Turbine from Endurance Wind Power". AZoNetwork. 13 May 2010. Retrieved 20 September 2013.
  7. ^ Forsyth, Trudy (20 May 2009). "Small Wind Technology" (PDF). National Renewable Energy Laboratory. Retrieved 20 September 2013.
  8. ^ a b "Milestones:Adams Hydroelectric Generating Plant, 1895". IEEE Global History Network. Retrieved 12 September 2013.
  9. ^ Western Electrician, Volume 37. Electrician Publishing Company. 1906.
  10. ^ Mochizuki, Asahi (October 2011). "JRTR Speed-up Story 2 Part 2: Speeding-up Conventional Lines and Shinkansen" (PDF). Japan Railway & Transport Review (58). Retrieved 12 September 2013.
  11. ^ "The Railway Power Stations of New York City". IEEE Global History Network. Retrieved 12 September 2013.
  12. ^ "Milestones:Ames Hydroelectric Generating Plant, 1891". IEEE Global History Network. Retrieved 21 September 2013.
  13. ^ a b "St Louis Municipal Electric Power Plant". Western Electrician. 30 (1–26): 387. 1902. Retrieved 21 September 2013.
  14. ^ "The Walchensee Power Plant. A Technological Jewel in the Alps" (PDF). e.on Wesserkraft. Retrieved 21 September 2013.
  15. ^ "Facts & Figures". Safe Harbor Water Power Corporation. Retrieved 21 September 2013.
  16. ^ "Neckarwestheim I darf nicht länger laufen. Bundesumweltministerium lehnt Strommengenübertragung von Block II auf Block I ab". Federal Ministry for the Environment, Nature Conservation and Nuclear Safety (Germany). 12 June 2008. Retrieved 21 September 2013.

Read other articles:

Disambiguazione – Se stai cercando il sovrano del Regno delle Due Sicilie che regnò dal 1817 al 1825, vedi Ferdinando I delle Due Sicilie. Ferdinando I di NapoliBusto di Ferdinando I di Napoli, XV secolo, Museo del LouvreRe di NapoliStemma In carica27 giugno 1458 –25 gennaio 1494 PredecessoreAlfonso I SuccessoreAlfonso II Altri titoliDuca di Calabria (1443-1458) NascitaValencia, 2 giugno 1423 MorteNapoli, 25 gennaio 1494 (70 anni) Luogo di sepolturaSacrestia di San Domen...

 

 

Frank Bello (lahir 9 Juli 1965 di Bronx, New York) adalah bassist kelompok musik Anthrax, menggantikan Dan Lilker sejak album Spreading the Disease. Ia hengkang dari Anthrax pada 2004 dan bergabung dengan Helmet, tetapi sekarang telah bergabung kembali. lbsAnthrax Scott Ian Charlie Benante Frank Bello Joey Belladonna Jonathan Donais Dan Lilker Greg D'Angelo Neil Turbin Dan Spitz Matt Fallon John Bush Paul Crook Dan Nelson Rob Caggiano David Weiss John Connelly Paul Kahn Kenny Kushner Greg Wal...

 

 

يفغيني كافلنيكوف معلومات شخصية الميلاد 18 فبراير 1974 (العمر 50 سنة)سوتشي, الاتحاد السوفياتي الطول 1.90 م (6 قدم 3 بوصة) الإقامة سوتشي, روسيا الجنسية روسيا (1992–) الاتحاد السوفيتي (1974–1992)  الوزن 84 كـغ (185 رطل؛ 13.2 ستون) استعمال اليد اليد اليمنى , الضربة الخلفية باليد�...

Complete set of nucleic acid sequences for humans For a non-technical introduction to the topic, see Introduction to genetics. Genomic informationSchematic representation of the human diploid karyotype, showing the organization of the genome into chromosomes, as well as annotated bands and sub-bands as seen on G banding. This drawing shows both the female (XX) and male (XY) versions of the 23rd chromosome pair. Chromosomal changes during the cell cycle are displayed at top center. The mitocho...

 

 

Pour les articles homonymes, voir Fitz-James (homonymie). Charles de Fitz-James Titre 4e duc de Fitz-James et pair de France (1736-1769) Prédécesseur François de Fitz-James Successeur Jacques-Charles de Fitz-James Allégeance Royaume de France Grade militaire Maréchal de France Commandement Commandant de la province de Languedoc Gouvernement militaire Gouverneur du Limousin Conflits Guerre de Succession de PologneGuerre de Succession d'AutricheGuerre de Sept Ans Distinctions Maison de Fi...

 

 

Human-made shapes and patterns of rocks placed on the ground The examples and perspective in this article deal primarily with North America and do not represent a worldwide view of the subject. You may improve this article, discuss the issue on the talk page, or create a new article, as appropriate. (February 2018) (Learn how and when to remove this template message) This article needs additional citations for verification. Please help improve this article by adding citations to reliable sour...

العلاقات البنمية البولندية بنما بولندا   بنما   بولندا تعديل مصدري - تعديل   العلاقات البنمية البولندية هي العلاقات الثنائية التي تجمع بين بنما وبولندا.[1][2][3][4][5] مقارنة بين البلدين هذه مقارنة عامة ومرجعية للدولتين: وجه المقارنة بنما بولند...

 

 

1981 American horror film by Lawrence D. Foldes Don't Go Near the ParkPoster artDirected byLawrence D. FoldesWritten byLawrence D. FoldesStory byLinwood ChaseProduced byLawrence D. FoldesStarring Aldo Ray Meeno Peluce Tamara Taylor Robert Gribbin Barbara Monker Linnea Quigley Chris Riley CinematographyWilliam DeDiegoEdited byDan PerryMusic byChris LedesmaProductioncompanyStar CinemaDistributed byCardinal IV Film DistributorsCannon FilmsRelease date September 11, 1981 (1981-09-1...

 

 

Paul McShane McShane bermain untuk Hull CityInformasi pribadiNama lengkap Paul David McShane[1]Tanggal lahir 6 Januari 1986 (umur 38)[1]Tempat lahir Kilpedder, Republik IrlandiaTinggi 1,83 m (6 ft 0 in)Posisi bermain BekInformasi klubKlub saat ini Manchester UnitedNomor 62Karier junior St Joseph's Boys2002–2004 Manchester UnitedKarier senior*Tahun Tim Tampil (Gol)2004–2006 Manchester United 0 (0)2004–2005 → Walsall (pinjaman) 4 (1)2005–2006 → B...

Politics of Poland Government Constitution of Poland Law Human rights Legislature Parliament of Poland Current Parliament Sejm Marshal Szymon Hołownia (PL2050) Deputy Marshals Senate Marshal Małgorzata Maria Kidawa- Błońska (PO) Deputy Marshals Executive President of Poland Andrzej Duda (I) Prime Minister of Poland Donald Tusk (PO) Cabinet Ministries Judiciary Supreme Court of Poland First President Małgorzata Manowska Constitutional Tribunal President Julia Przyłębska Supreme Administ...

 

 

BäherdenNegara TurkmenistanProvinsiProvinsi AhalDistrikDistrik BaharlyPopulasi (sensus 1989)[1] • Total16.823 Bäherden[2] adalah sebuah kota dan pusat Distrik Baharly di barat daya Turkmenistan di Provinsi Ahal. Terletak di tepi utara pegunungan Kopet Dag, barat daya dari kota Archman. Referensi ^ Population census 1989, Demoscope Weekly, No. 359-360, 1-18 January 2009 (search for Туркменская ССР) (Rusia) ^ Парламент Туркме�...

 

 

Material which is used for construction purposes For other kinds of building materials, see Household hardware, Biology, and Star formation. This article needs additional citations for verification. Please help improve this article by adding citations to reliable sources. Unsourced material may be challenged and removed.Find sources: Building material – news · newspapers · books · scholar · JSTOR (December 2013) (Learn how and when to remove this messa...

Latin Catholic jurisdiction in Mexico Archdiocese of MoreliaArchidioecesis MoreliensisArquidiócesis de MoreliaCatedral de San SalvadorLocationCountryMexicoEcclesiastical provinceMoreliaStatisticsArea6,952 sq mi (18,010 km2)Population- Total- Catholics(as of 2013)2,612,3602,455,618 (94%)Parishes236InformationDenominationCatholic ChurchSui iuris churchLatin ChurchRiteRoman RiteEstablished11 August 1536 (487 years ago)CathedralCathedral of the Transfiguration,Morel...

 

 

  关于与「內閣總理大臣」標題相近或相同的条目页,請見「內閣總理大臣 (消歧義)」。 日本國內閣總理大臣內閣總理大臣紋章現任岸田文雄自2021年10月4日在任尊称總理、總理大臣、首相、阁下官邸總理大臣官邸提名者國會全體議員選出任命者天皇任期四年,無連任限制[註 1]設立法源日本國憲法先前职位太政大臣(太政官)首任伊藤博文设立1885年12月22日,...

 

 

This template does not require a rating on Wikipedia's content assessment scale.It is of interest to the following WikiProjects:Trains Trains Portal This template is within the scope of WikiProject Trains, an attempt to build a comprehensive and detailed guide to rail transport on Wikipedia. If you would like to participate, you can visit the project page, where you can join the project and/or contribute to the discussion. See also: WikiProject Trains to do list and the Trains Portal.TrainsW...

本條目存在以下問題,請協助改善本條目或在討論頁針對議題發表看法。 此條目需要編修,以確保文法、用詞、语气、格式、標點等使用恰当。 (2013年8月6日)請按照校對指引,幫助编辑這個條目。(幫助、討論) 此條目剧情、虛構用語或人物介紹过长过细,需清理无关故事主轴的细节、用語和角色介紹。 (2020年10月6日)劇情、用語和人物介紹都只是用於了解故事主軸,輔助�...

 

 

South Korean smelting company Korea Zinc Company, Ltd.Native name고려아연주식회사Company typePublicTraded asKRX: 010130IndustryMetallurgyFounded1974; 50 years ago (1974)HeadquartersSeoul, South KoreaRevenue ₩11.2194 trillion[1] (2022)Operating income ₩919.2 billion[1] (2022)Net income ₩798.3 billion[1] (2022)Total assets ₩12.0979 trillion[1] (2022)Total equity ₩9.2317 trillion[...

 

 

Disambiguazione – Jonio rimanda qui. Se stai cercando l'omonima stazione della metropolitana di Roma, vedi Jonio (metropolitana di Roma). Mar IonioIl mar Ionio presso ZanteParte diMar Mediterraneo Stati Italia Grecia RegioniPuglia, Calabria, Basilicata, Sicilia Coordinate38°06′04″N 18°17′41″E38°06′04″N, 18°17′41″E DimensioniSuperficiecirca 200 000 km² Profondità massima5 270 m Profondità media4 000 m IdrografiaIsoleIsole Ionie InsenatureGo...

Riccardo Villari Sottosegretario di Stato al Ministero per i beni e le attività culturaliDurata mandato5 maggio 2011 –16 novembre 2011 ContitolareFrancesco Giro Capo del governoSilvio Berlusconi PredecessoreElena MontecchiAndrea MarcucciDanielle Mazzonis SuccessoreRoberto Cecchi Presidente della Commissione parlamentare di Vigilanza RaiDurata mandato13 novembre 2008 –21 gennaio 2009 PredecessoreMario Landolfi SuccessoreSergio Zavoli Senatore della Repubblica I...

 

 

Звонкий увулярный взрывной согласныйɢ Изображение Юникод (hex) U+262 HTML (decimal) ɢ X-SAMPA G\ Киршенбаум G МФА Брайля ⠔⠛ образец звука Звонкий увулярный взрывной согласный — согласный звук, встречающийся в некоторых языках. Обозначается знаком ɢ в МФА и G\ в X-SAMPA. Содержание 1 Хар...